  • Type: Occupancy Sensor
  • Color: White
  • MPN: PCC1D-W
  • Compatible Brand: Leviton
  • UPC: 078477688724
  • Model: PCC1D-W
  • Shipping Profile ID: 58890620020
  • Brand: Leviton Manufacturing
  • Country/Region of Manufacture: Unknown
  • Condition: New

    Description

    By combining a 1-10V dimming photocell with the power of a Leviton power pack, the Leviton Provolt™ Line Voltage Photocell (Ceiling Mount) is an all-in-one mini daylight harvesting system — no separate power pack needed. The photocell includes two removable light pipes for either open or closed loop applications. It's an elegant solution to maximize natural light indoors (with the bonus of energy savings), while automatically adjusting your dimmable lamps and light fixtures as daylight levels change, always maintaining your Desired Light Level (DDL) for the room.
    Complete open and closed loop daylight harvesting system
    Works with momentary or maintained switches to adjust dimmable lights
    Combines a dimming photocell with a Leviton power pack
    Ideal for daylight harvesting and lighting control in spaces with windows
    Includes two removable light pipes for open and closed loop applications
    Auto-calibration feature helps maximize daylight harvesting
    1-10V sinking operation supports a dimmable LED driver or electronic ballast
    Meets CA Title 20/24 and ASHRAE 90.1 energy-efficiency requirements
    How It Works: Auto-Dimming Your Connected Lights
    Ideal for an indoor living space with windows, the photocell detects daylight and works with your existing light switch to adjust the connected lights (dim up/down, turn on/off) according to daylight levels.
    The photocell controls a 1-10 VDC dimmable ballast or LED driver to achieve maximum energy savings while maintaining a minimum light level. The photocell will increase the light output until the Desired Light Level (DDL) is reached. As the light level changes, the photocell will reduce or increase the dim level in order to maintain the DDL. (There is an adjustable Fade Rate dial to make the light level transitions unnoticeable to room occupants.)
    What happens when ...
    When no daylight is detected, the photocell turns up your light to operate at its full brightness level.
    When daylight increases in the room, the photocell dims the light.
    When lots of natural daylight is providing so much light that your electrical lights reach their minimum dim level (and if the Dim to Off setting is enabled), the photocell will switch off those lights. The lights will remain off until the light level drops below the DDL for 30 seconds. The lights will then be turned on, with the light source set at its minimum dim level.
    Daylight Harvesting Applications
    Daylight harvesting is an automated lighting control strategy that maximizes the use of natural daylight and minimizes the use of electrical (artificial) light in response to the availability of natural light in a space. The photocell uses three types of daylight harvesting applications:
    Closed loop:
    Photocell detects total photo-metric light from daylight or electric sources in the space.
    Open loop:
    Photocell detects daylight OR electric light only; requires manual calibration.
    Adjustable daylight design levels:
    Normal (OFF) and Auto-Calibration.
    Auto-Calibrates for Accurate Time-of-Day Adjustments
    Not only is it simple to install (see details below), the photocell features patented daylighting design level technology to auto-calibrate a room for more accurate daylight harvesting operation (in closed loop applications). The photocell maintains the architectural lighting design level through calculation and measurement of ambient (natural and artificial) lighting and fine dimming adjustment.
    Manual calibration is also an option for even more precise fine tuning, as well as open loop applications.
    Meets Energy Efficiency & Safety Standards
    The photocell complies with growing energy regulations and includes a connection for emergency lighting and demand response to meet California Title 24 and ASHRAE Standard 90.1 2010.
    Additional Photocell Features
    Lamp Burn-In Mode:
    When active, forces the load(s) ON, at full brightness, for seasoning fluorescent lights. Typically this is done for ~100 hours. Consult lamp manufacturer for specifics.
    Dim to OFF:
    If enabled, load(s) will be switched off when minimum dimming output is reached and light is not needed. If disabled, load(s) will remain on, at minimum dimming output, when light is not needed.
    Forced ON:
    User forces lights on for 2 hours through wall switch/station, auto-exit to daylighting state.
    Forced OFF:
    User forces light off through wall switch/station.
    External Input Select:
    Selects functionality of the external input: manual switch or demand response.
    Power-Up Restore:
    If enabled, the load(s) will be switched off upon power-up if the manual switch was previously used to turn the load(s) off (Forced-OFF). External Input Select must be set to manual switch for this setting to be functional.
    Test Mode:
    When enabled, the fade rate will be set to 30 seconds for 60 minutes.
    Demand Response:
    Accepts a low voltage contact closure input. When Demand Response is active, the maximum allowable dimming output is set to the value selected by the red Demand Response dial.
    Emergency Interface:
    Accepts a low voltage contact closure input. When the Emergency input is active, the load(s) will be forced ON, at full brightness. "Fail-safe" circuitry assures lights ON to meet life safety requirements (NFPA101).
    Manual Switch:
    Accepts a low voltage contact closure input for a toggle or momentary switch.
    Photocell Detection Range:
    1-16,000 Lux.
    LED Enable/Disable:
    Flexibility for light sensitive requirements.
    Installation Details
    Designed for either new construction or retrofitting, the photocell mounts to the ceiling with the included mounting plate. It works in conjunction with a 1-10 VDC dimmable ballast (electronic or magnetic) or an LED driver via wiring. It also auto-detects a momentary or maintained wall switch/station for manual override control.
    The photocell easily installs into a J-box with the included Leviton-exclusive screw guides, coasters, and terminal blocks. Faceplate ridges make it easy to identify pressure points for simple press and release installation. The photocell also includes a 4"x4" cosmetic adapter to enhance the final installation and alleviate potential contrast between the sensor and backbox.
    Contents
    Provolt™ Line Voltage Photocell
    (2) Removable Light Pipes (flat or angled)
    Mounting Plate, 4" x 4"
    Screws, #6-32 x 1-1/2"
    Low-Voltage Connector
    Tubing Barrier
    Emergency Label
    Notes
    Neutral wire is required to connect to an existing light switch.
    This 1-zone model (PCC1D-W) does not support dual zone operation.
    Technical Details
    Manufacturer Part #:
    PCC1D-W
    UPC:
    078477688724
    Model:
    Single 1-10V dimming with single relay ON/OFF for single zone day/night single office or corridor
    Electrical
    Input Voltage:
    120V, 50/60 Hz; 240V, 50 Hz; 277V, 50/60 Hz
    Load Rating:
    120V: 8A, Electronic Ballast, 800W/VA, Tungsten, Ballast, 1/4 HP Motor
    240V: 6A/6AX Electronic Fluorescent or Magnetic Ballast, 1200W/VA, 1/3 HP Motor
    277V: 5A, Electronic Ballast, 1200VA, 1/3 HP Motor
    Current Consumption:
    60-30mA
    Light Detection Range:
    1-1,600 FC (10-16,000 LUX)
    LED Loads:
    400W/1-10V sinking
    Fade Rate:
    30 Min
    Demand Response:
    75 percent (MFG Range 1-1600FC)
    Environmental
    Operating Temperature:
    32° to 104°F (0° to 40°C)
    Storage Temperature:
    -14° to 160°F (-26° to 71°C)
    Relative Humidity:
    10 to 90 percent non-condensing
    LED Indicators
    Red or Blue:
    Solid during device failure
    Red:
    Blinking during manual calibration
    Green:
    Solid during auto calibration
    Blinking during burn-in (dimming models only)
    Blue:
    Blinking when lights are off (daylight, wall station, demand response)
    Yellow:
    Solid when device is in emergency mode
    Blinking in test mode
    Other
    Mounting Height:
    8 to 20 feet (2.43 to 6.09 meters)
    Listings:
    CA Title 20/24 Compliant
    ASHRAE Standard 90.1 2010 Compliant
    UL 773A (Occupancy Standard)
    UL 924 (Emergency Equipment)
    cUL Listed
    NOM Certified
    RoHS Compliant
    NY LLC48 Compliant
    FCC compliant
    Warranty:
    5-Year Limited